氧在不同温度和氯化物浓度的水中饱和含量表
2007-06-30 17:55阅读:
氧在不同温度和氯化物浓度的水中饱和含量表(气压101.3kPa)
温度
|
CS
|
ΔCS
|
温度
|
CS
|
ΔCS
|
℃
|
mg/L
|
mg/L
|
℃
|
mg/L
|
mg/L
|
0
|
14.64
|
0.0925
|
20
|
9.08
|
0.0481
|
1
|
14.22
|
0.0890
|
21
|
8.90
|
0.0467
|
2
|
|
13.82
0.0857
|
22
|
8.73
|
0.0453
|
3
|
13.44
|
0.0827
|
23
|
8.57
|
0.0440
|
4
|
13.09
|
0.0798
|
24
|
8.41
|
0.0427
|
5
|
12.74
|
0.0771
|
25
|
8.25
|
0.0415
|
6
|
12.42
|
0.0745
|
26
|
8.11
|
0.0404
|
7
|
12.11
|
0.0720
|
27
|
7.96
|
0.0393
|
8
|
11.81
|
0.0697
|
28
|
7.82
|
0.0382
|
9
|
11.53
|
0.0675
|
29
|
7.69
|
0.0372
|
10
|
11.26
|
0.0653
|
30
|
7.56
|
0.0362
|
11
|
11.01
|
0.0633
|
31
|
7.43
|
|
12
|
10.77
|
0.0614
|
32
|
7.30
|
|
13
|
10.53
|
0.0595
|
33
|
7.18
|
|
14
|
10.30
|
0.0577
|
34
|
7.07
|
|
15
|
10.08
|
0.0559
|
35
|
6.95
|
|
16
|
9.86
|
0.0543
|
36
|
6.84
|
|
17
|
9.66
|
0.0527
|
37
|
6.73
|
|
18
|
9.46
|
0.0511
|
38
|
6.63
|
|
19
|
9.27
|
0.0496
|
39
|
6.53
|
|
1)表中的栏2是氧溶解度(C
S),以每升水含若干毫克表示:在101.3kPa压力下,纯水中含有带饱和水蒸汽的空气时含氧量为20.94%(V/V)。
2)氧在水中的溶解度随含盐度的增加而降低,其关系呈线性关系,实际上水的含量可高达35g/L,含盐量以每升水中含多少克盐表示之,表中所列的ΔC
S是进行校正时每升每克盐浓度要减去的数值。因此氧在含有ng/L盐的水中的溶解度,要用对应的纯水的氧溶解度减去nΔC
S的数值便可求得。
6.3.3 无氧水的制备
在配制250mg/L的5%亚硫酸钠(Na
2SO
3)溶液,可加入适量的氯化钴(CoCl
2)做催化剂。
6.3.4 饱和溶氧水的制备
将恒温水浴的水温恒定在所要测定的温度值上,然后用空气泵向水中连续鼓泡2小时以上。
6.4 响应时间和零值误差的测试
在空气中,将溶氧测定仪的示值调至为10.0mg/L,待值稳定后,把传感器放入无氧水中,同时用秒表计时,当示值下降至1 mg/L
时所需时间,即为响应时间;然后再继续记时至5min末,溶氧测定仪的示值即为残余电流引起的零值误差。