ABAQUS文件扩展名详解(ABAQUS File Extensions)
2013-08-09 21:20阅读:
File extensions
------------------------
abq
State file, only used by Abaqus/Explicit. It is written by the
analysis, continue, and recover options. It is read by the convert
and recover options. This file is required for restart.
axi
Symmetric model data file, only used by Abaqus/Standard. It is
written during symmetric model generation by the datacheck and
analysis options.
bsp
Text file containing beam cross-section properties for meshed
section profiles. It is written by Abaqus/Standard during meshed
beam cross-section generation.
cid
Auto-release file, which contains information needed for license
recovery and suspension.
com
Command file, created by the Abaqus execution procedure.
dat
Printed output file. It is written by the analysis, datacheck,
parametercheck, and continue options. Abaqus/Explicit does not
write analysis results to this file.
eig
Lanczos eigenvector file. This is a temporary scratch file that i
s used to store the eigenvectors calculated by the Lanczos
eigensolver during the solution procedure.
f
User subroutine or other special-purpose FORTRAN file.
fct, uft
Sparse solver factor files. These temporary scratch files are used
by the sparse solver in Abaqus/Standard. The uft file is created
only when the unsymmetric solver is used.
fil
Results file. It is written by the analysis and continue options in
Abaqus/Standard and by the convert=select and convert=all options
in Abaqus/Explicit.
fin
Results file created when changing the format of the .fil file
using the abaqus ascfil command. It can be in either ASCII or
binary format. (See “Execution procedure for ASCII translation of
results (.fil) files,” Section 3.2.9.) The ASCII format is
convenient for data transfer between machines that do not have
compatible binary data formats.
inp
Analysis input file. It is read when the analysis, datacheck, and
parametercheck options are selected.
ipm
Interprocess message file. It is written when an analysis is run
from Abaqus/CAE, and it contains a log of all messages sent from
Abaqus/Standard or Abaqus/Explicit to Abaqus/CAE.
lck
Lock file for the output database. This file is written whenever an
output database file is opened with write access; it prevents you
from having simultaneous write permission to the output database
from multiple sources. It is deleted automatically when the output
database file is closed or when the analysis that creates it ends.
The ask_delete environment file parameter setting will not affect
the lock file.
lnz
Lanczos vector file. This is a temporary scratch file that is used
to store the Lanczos vectors and weighted Lanczos vectors.
log
Log file, which contains start and end times for modules run by the
current Abaqus execution procedure.
mdl
Model file. It is written by the datacheck option in
Abaqus/Standard and Abaqus/Explicit. It is read and can be written
by the analysis and continue options in Abaqus/Standard. It is read
by the analysis and continue options in Abaqus/Explicit. Multiple
model files may exist if the element operations are executed in
parallel in an Abaqus/Standard analysis. In such a case a process
identifier is attached to the file name. This file is required for
restart.
msg
Message file. It is written by the analysis, datacheck, and
continue options in Abaqus/Standard and Abaqus/Explicit. Multiple
message files may exist if the element operations are executed in
parallel in an Abaqus/Standard analysis. In such a case a process
identifier is attached to the file name.
nck
Nickname file used by Abaqus/Standard. It stores a set of internal
identifiers for the degrees of freedom in a model.
odb
Output database. It is written by the analysis and continue options
in Abaqus/Standard and Abaqus/Explicit. It is read by the
Visualization module in Abaqus/CAE (Abaqus/Viewer) and by the
convert=odb option. This file is required for restart.
opr
Sparse solver operator file, which is a temporary scratch file used
by the sparse solver in Abaqus/Standard.
pac
Package file, which contains model information and is used by
Abaqus/Explicit only. It is written by the analysis and datacheck
options. It is read by the analysis, continue, and recover options.
This file is required for restart.
par
Modified version of original parametrized input file showing input
parameters and their values.
pes
Modified version of original parametrized input file showing input
free of parameter information (after input parameter evaluation and
substitution has been performed).
pmg
Parameter evaluation and substitution message file. It is written
when the input file is parametrized.
prt
Part file. This file is used to store part and assembly information
and is created even if the input file does not contain an assembly
definition. The part file is required for restart, import,
sequentially coupled thermal-stress analysis, symmetric model
generation, and underwater shock analysis, even if the model is not
defined in terms of an assembly of part instances. This file may
also be needed for submodeling analysis.
psf
Python scripting file. You must create this type of file to define
a parametric study.
res
Restart file, which contains information necessary to continue a
previous analysis. The restart file is written by the analysis,
datacheck, and continue options. It is read by any restarted
analysis.
scr
Lanczos scratch file. This is a temporary scratch file that is used
to hold temporary information required by the Lanczos solver.
sct
Perturbation results scratch file. This file temporarily holds
element results needed for output in Abaqus/Standard perturbation
steps.
sdb
Sparse solver database file. This is a temporary file that is used
by the sparse solver.
sel
Selected results file, used by Abaqus/Explicit. It is written by
the analysis, continue, and recover options and is read by the
convert=select option. This file is required for restart.
sim
Linear dynamics data file. It is written during the frequency
extraction procedure in SIM-based linear dynamics analyses (see
“Using the SIM architecture for mode-based linear dynamic analyses”
in “Dynamic analysis procedures: overview,” Section 6.3.1, for
details) and is used to store eigenvectors, substructure matrices,
and other modal system information. This file is required for
restart.
sol
Sparse solver file used to store the solution vectors for a
problem. This file is a temporary file used by the sparse solver in
Abaqus/Standard.
sst
Sparse solver scratch file. This temporary scratch file is used by
the sparse solver in Abaqus/Standard.
sta
Status file. Abaqus writes increment summaries to this file in the
analysis, continue, and recover options.
stt
State file. It is written by the datacheck option in
Abaqus/Standard and Abaqus/Explicit. It is read and can be written
by the analysis and continue options in Abaqus/Standard. It is read
by the analysis and continue options in Abaqus/Explicit. Multiple
state files may exist if the element operations are executed in
parallel in an Abaqus/Standard analysis. In such a case a process
identifier is attached to the file name. This file is required for
restart.
sup
Substructure file, used by Abaqus/Standard.
var
File containing information about the input file variations
generated by a parametric study.
023
Communications file. It is written by the analysis and datacheck
options and is read by the analysis and continue options.